The K7 Evaluation
System

Objective Data
for Complete Occlusal Analysis
The
K7 Evaluation System provides the dental clinician or
researcher with three distinctly different technologies for
measuring,
displaying and storing objective data on
physiologic and anatomical status and function. This objective
data enhances the doctor’s diagnostic and treatment
considerations with information not previously available.
The
K7 Evaluation System is supplied in a compact housing that
can be plugged in to the serial port of virtually any PC type
computer, desktop or laptop. Small and portable, the unit and
its peripheral apparatus can be quickly stored in the provided
protective case for ease of transportation. Windows based
software simplifies operation and color graphics make it easy
to distinguish overlapping data from multiple channels and to
print attractive reports for patient education, insurance or
referring doctors.
For over thirty years, Myotronics has been
dedicated to strong customer support. One small example is "Kevin's
Pearls". Registered owners of K6-I or K7 Evaluation
Systems can have helpful users tips sent by e-mail every week.
These tips from our head programming engineer aid customers in
deriving maximum benefits from their instruments.
A number of useful testing protocols referred
to as "Scans" are pre-programmed for the convenience of the
user. Additional custom protocols may be programmed by the
user to fulfill unique needs or preferences. The three
individual modules and their capabilities are listed below.
K7/CMS Computerized
Mandibular Scanner
(CMS - Jaw Tracking)
Multiple sensors in an extremely light weight
(four ounce) spectacle-like array, track the motion of a tiny
magnet attached to the lower incisal gingiva with adhesive
material. The configuration is totally non-invasive and,
unlike clutches, does not interfere with patient function. The
opposing sensors are wide apart permitting unobstructed access
to the oral cavity for taking bite registrations and other
clinical procedures, and the system is virtually immune from
effects of slight head motion or nearby metallic or electronic
interference. A patient education mode is included to simplify
patient understanding and staff training.
These scans are invaluable three dimensional representation of
mandibular rest, the relaxed neuromuscular path of closure,
centric occlusion, habitual path of closure and protrusive
guidance that allows the clinician to record an optimal
occlusal position.
K7/EMG Eight Channel
Electromyograph (EMG)
Utilizing high quality bipolar surface
electrodes, EMG data can be taken from up to eight
muscle
sites simultaneously and in real time. The program permits
taking electromyography data either at rest or in function.
All eight channels may be displayed simultaneously, for a
period of 15 seconds (one visual screen width). The K7/EMG
signal processing circuitry provides unsurpassed protection
against system noise or motion artifact. The patient education
mode permits quick and easy patient education as to status of
masticatory muscles.

These scans provide an objective measurement
of masticatory muscle electrical activity which accurately
represents the physiologic state of rest.
Model K7/ESG
Electrosonograph (ESG)
TMJ
Vibration (Sound) Evaluation System. A lightweight headset
holds highly sensitive vibration transducers over each TM
joint, enabling simultaneous, bilateral capture of tissue
vibrations emanating from joint sounds. Vibration (sound) data
is correlated to vertical dimension of opening and closing,
providing clinicians with valuable information to aid in
assessing the status of articular disk and joint function.
The ESG includes the ability to document TM
joint status through recording joint sound vibrations – simply
and non-invasively. |